TABLE I.
(A) Not constrained to AP | |||
---|---|---|---|
Initial value | Lower bound | Upper bound | |
A1 (μV) | 0.75 | 0 | ∞ |
L1 (ms) | 0.5 | 0 | 1 |
W1 (ms) | 0.3 | 0 | 0.7 |
A2 (μV) | 1 | 0 | ∞ |
L2 (ms) | 1.75 | 1 | 2.5 |
W2 (ms) | 0.2 | 0 | 0.7 |
(B) Constrained to AP | |||
---|---|---|---|
Initial value | Lower bound | Upper bound | |
A1 (μV) | 0.75 | 0 | ∞ |
L1 (ms) | L2 tester − 1.0 | 0.01 | L2 tester − 0.5 |
W1 (ms) | 0.3 | 0 | 0.7 |
A2 (μV) | 1 | 0 | ∞ |
L2 (ms) | L2 tester | L2 tester − 0.1 | L2 tester + 0.1 |
W2 (ms) | 0.2 | 0 | 0.7 |