Skip to main content
. 2021 Nov 15;12:711326. doi: 10.3389/fmicb.2021.711326

TABLE 1.

Minimum inhibitory concentration values (mg/ml) of limonene, RuL3, and microencapsulated RuL3 against Escherichia coli, Staphylococcus aureus, Listeria monocytogenes, and Enterococcus faecalis.

MIC mg/ml
E. coli S. aureus L. monocytogenes E. faecalis
Limonene 12.5 12.5 12.5 12.5
RuL3 0.4 0.4 0.4 0.8
Microencapsulated RuL3 0.1 0.1 0.1 0.4