Skip to main content
. 2021 Dec 5;115:108190. doi: 10.1016/j.asoc.2021.108190

Table 3.

Mean precision, recall and F1-score results obtained at the test stage for the classification of chest X-ray images between Healthy vs Pneumonia/Covid-19 cases.

Architecture Class Precision Recall F1-score
DenseNet-121 Healthy 0.9915 ± 0.0032 0.9794 ± 0.0207 0.9853 ± 0.0094
Pneumonia/Covid-19 0.9615 ± 0.0381 0.9833 ± 0.0062 0.9719 ± 0.0173

DenseNet-161 Healthy 0.9869 ± 0.0113 0.9891 ± 0.0050 0.9880 ± 0.0076
Pneumonia/Covid-19 0.9783 ± 0.0104 0.9734 ± 0.0235 0.9758 ± 0.0159

ResNet-18 Healthy 0.9806 ± 0.0120 0.9855 ± 0.0071 0.9830 ± 0.0082
Pneumonia/Covid-19 0.9706 ± 0.0141 0.9624 ± 0.0209 0.9663 ± 0.0130

ResNet-34 Healthy 0.9888 ± 0.0092 0.9821 ± 0.0116 0.9853 ± 0.0033
Pneumonia/Covid-19 0.9642 ± 0.0248 0.9798 ± 0.0161 0.9716 ± 0.0071

VGG-16 Healthy 0.9842 ± 0.0078 0.9831 ± 0.0045 0.9837 ± 0.0055
Pneumonia/Covid-19 0.9658 ± 0.0125 0.9688 ± 0.0171 0.9672 ± 0.0131

VGG-19 Healthy 0.9735 ± 0.0065 0.9806 ± 0.0131 0.9770 ± 0.0088
Pneumonia/Covid-19 0.9618 ± 0.0257 0.9477 ± 0.0152 0.9546 ± 0.0182