Skip to main content
. 2021 Jan 8;62(3):539–547. doi: 10.1007/s10840-020-00926-4

Table 4.

Average and Minimal distances measured from the core of the LIA, LRA and Foci to the border of the LVA

LVA definition (mV) Average distance (mm) Minimal distance (mm) Average distance (mm) Minimal distance (mm) Average distance (mm) Minimal distance (mm)
LIA to center LVA LIA to center LVA LRA to center LVA LRA to center LVA F to center LVA F to center LVA
0.2 28.41 ± 15.56 18.95 ± 16.64 29.03 ± 19.57 18.07 ± 13.86 35.62 ± 19.78 26.70 ± 19.44
0.3 23.98 ± 13.80 17.04 ± 14.27 26.01 ± 18.24 15.32 ± 13.44 33.47 ± 19.97 25.35 ± 19.16
0.4 23.33 ± 16.09 14.48 ± 15.09 24.29 ± 19.73 14.61 ± 14.28 30.68 ± 19.38 22.32 ± 18.54
0.5 19.54 ± 13.22 10.46 ± 13.75 17.87 ± 15.79 10.12 ± 13.36 26.26 ± 19.16 19.75 ± 19.52
0.6 15.03 ± 13.47 7.35 ± 13.59 13.85 ± 15.48 6.66 ± 13.37 21.81 ± 16.36 14.35 ± 19.24
0.7 14.52 ± 13.22 5.09 ± 13.95 12.03 ± 13.60 4.58 ± 10.14 19.33 ± 13.32 10.12 ± 14.83
0.8 12.49 ± 13.87 3.39 ± 12.74 9.18 ± 14.05 3.64 ± 10.88 16.92 ± 13.02 7.89 ± 14.25
0.9 11.43 ± 12.20 1.75 ± 12.12 5.18 ± 12.06 1.21 ± 9.22 11.35 ± 12.03 4.65 ± 12.49
1 6.75 ± 10.24 − 0.44 ± 9.75 4.12 ± 11.40 0.19 ± 7.41 10.12 ± 10.04 2.79 ± 9.97

LVA low-voltage areas; LIA localized irregular activity; LAR localized rotational activation