Skip to main content
. 2021 Dec 1;20:111–116. doi: 10.1016/j.phro.2021.11.007

Table 1.

Overview of all clinical goals used for the optimized plans in this study. Percentages are indicating the relative volume of the ROI and goals are set with a prescription dose of 40.05 Gy. The ROI names follow the nomenclature according to AAPM TG 263 [15]. The clinical goals are based on the consensus statement of the Dutch society for radiation Oncology [18].

ROI Description Goal
PTVp PTV of the whole left breast cropped with 5 mm from external D98% ≥ 38.0 Gy
D2% ≤ 42.8 Gy
39.6 Gy ≤ Dmean ≤ 40.4 Gy
PTVn1n2 PTV of lymph nodes level 1&2 cropped with 5 mm from external D98% ≥ 38.0 Gy
D2% ≤ 42.8 Gy
PTVn3n4 PTV of lymph nodes level 3&4 cropped with 5 mm from external D98% ≥ 38.0 Gy
D2% ≤ 42.8 Gy
Heart Heart ROI Dmean ≤ 2.5 Gy
Lungs Lungs ROI Dmean ≤ 6.0 Gy
V5Gy ≤ 50%
External-PTV Full patient body, without all PTVs V42.85y ≤ 10 cm3
Humerus-PRV10 Humerus ROI with uniform expansion of 10 mm V38Gy ≤ 2 cm3
Breast_CL Contralateral breast Dmean ≤ 1 Gy
Thyroid Thyroid ROI V30Gy ≤ 50%
Esophagus Esophagus ROI V30Gy ≤ 5%