Comparison of AMTDII and AMPLICOR amplification assays with smear and culture results and clinical data for extrapulmonary specimensa

Patient status (no. of specimens) No. of specimens positive byb:
AMTDII AMPLICOR
Smear and culture positive (25) 22 [3] 23 (1)
Smear negative, culture positive (8) 7 [1] 7 (1)
Smear and culture negative with final diagnosis of TB (8) 5 [0] 4 (2)
All TB positive (41) 34 [4] 34 (4)
Smear and culture negative, non-TB disease (138) 0 0
Isolation of NTM (11) 0 0
a

P values were not significant. 

b

Values in brackets represent the number of specimens which turned out to be positive when retrospectively tested after dilution. Values in parentheses represent the number of specimens showing a negative amplification control which turned out to be positive when retested after dilution.