. 2021 Nov 23;9:649221. doi: 10.3389/fbioe.2021.649221

TABLE 3.

Accuracy of the synthetic post-therapeutic OCT images in determining the CMT and SRF in the evaluation experiment.

Baseline 1-month prediction 3-month prediction
CMT (μm) Real images Synthetic images Real images MAE (61 eyes) Synthetic images Real images MAE (31 eyes)
Hd-PDT 333.29 ± 132.53 198.32 ± 64.12 189.06 ± 61.49 28.21 ± 12.34 194.54 ± 63.71 187.29 ± 61.02 19.36 ± 8.44
SML 375.41 ± 151.86 264.39 ± 79.58 254.86 ± 77.67 34.14 ± 14.56 254.41 ± 78.01 248.32 ± 77.77 28.65 ± 10.28
CL 334.23 ± 121.82 244.17 ± 95.47 234.69 ± 93.95 31.12 ± 13.52 230.24 ± 76.54 220.23 ± 76.21 21.44 ± 9.68
Total 357.83 ± 142.32 240.56 ± 83.28 228.24 ± 81.08 30.15 ± 13.28 231.45 ± 77.64 220.92 ± 75.76 22.46 ± 9.71
SRF (μm) Real images Synthetic images Real images MAE Synthetic images Real images MAE
Hd-PDT 206.54 ± 119.56 77.84 ± 79.84 75.65 ± 78.15 19.21 ± 20.47 65.47 ± 79.87 63.26 ± 79.14 17.84 ± 20.17
SML 229.65 ± 135.11 86.77 ± 87.65 82.52 ± 82.44 24.26 ± 25.54 74.18 ± 89.74 71.25 ± 88.62 21.04 ± 23.83
CL 210.32 ± 117.48 80.19 ± 84.21 79.34 ± 80.89 22.16 ± 24.05 69.05 ± 86.92 67.94 ± 85.87 19.83 ± 22.86
Total 217.56 ± 130.36 81.57 ± 81.54 78.35 ± 80.42 22.44 ± 23.14 70.07 ± 87.19 68.04 ± 86.53 19.33 ± 22.08

CMT, central macular thickness; SRF, subretinal fluid; PDT, photodynamic therapy, half-dose PDT (hd-PDT) was applied in our clinical protocol; SML, subthreshold micropulse laser treatment; CL, conventional laser treatment; MAE, mean absolute error, values are presented as the means ± standard deviations.