Table 4.
Biopsy requirements
Forms required Equipment | Before performing an embryo biopsy, it is mandatory to fill form F and G in duplicate |
Inverted microscope with light field objectives (4×, 10×, 20×) and Hoffman objective (40×) with heated stage | |
Holding micromanipulator and microinjector | |
Biopsy micromanipulator and microinjector | |
Laser shot system (mandatory) | |
Laminar flow hood incorporated with UV light (mandatory)** | |
Laminar hood in different rooms (advisable)** | |
Stereo Zoom microscope for tubing | |
Deep freezer (−20°C) (mandatory) | |
Minicentrifuge (6000 rpm) | |
Micropipettes with adjustable volumes (0.5-10 µL; 20-200 µL; 100-1000 µL) | |
Consumables/disposables | Biopsy and holding micropipettes for embryo biopsy |
Flexipets/denudation pipettes/glass capillaries for embryo and biopsy manipulation | |
Barrier tips for micropipettes: Sterile tips, with white filter; RNase, DNase, pyrogen, and DNA free (should fit your micropipettes 0.5-10 µL and 20-200 µL or 100-1000 µL) | |
Use surface decontaminant like ethanol | |
Sterile disposable surgical gown (mandatory) | |
Sterile latex/nitrile gloves (nonpowdered only) | |
Medium | The use of standard IVF culture medium during biopsy is “acceptable,” but its effectiveness may be highly dependent upon the developmental stage of the embryo biopsied |
IVF=In vitro fertilization, UV=Ultraviolet