Stan et al., 2015 P300 Hand orthosis None 9 8 Flashes: 75 ms Flash-time: 100 ms NS LDA 100 NS NS
Kwak et al., 2017 SSVEP Lower limb exoskeleton None 7 8 5 LEDs flashing at 9, 11, 13, 15, 17 Hz with 50% DC NR CNN Static: 99.28, Ambulatory: 94.93 NS 10-fold CV
Kwak et al., 2015 SSVEP Lower limb exoskeleton None 11 8 5 LEDs: 9, 11, 13, 15, 17 Hz with 50% DC CCA k-nearest neighbors 91.3 32.9 5-fold CV
Delijorge et al., 2020 P300 Robotic hand orthosis 8 ALS 18 8 2–30 random flashes CCA RLDA Offline: 78.7 (target), 85.7 (non-target). Online: 89.83 18.13 5-fold CV
Zhao et al., 2016 SSVEP FES, upper limb rehabilitation None 5 14 Squares flashing at 12, 15, 20 Hz Power spectrum LDA Offline: 79.37–85.13 Online: 54.32–87.5 Offline: 27.54 10-fold CV
Tidoni et al., 2017 SSVEP VR, Propioceptive Stimulation 3 SCI 18 8 3 × 3 grid. flash-time: 133.33 ms dark-time: 83.34 ms NS LDA 83.33 1.55 NS
Yao et al., 2011 SSVEP FES, upper limb rehabilitation None 4 8 White blocks of lights flickering at 6.82, 7.5, 8.33, 9.37, and 12.5 Hz 5 flickering frequencies and their harmonic components LDA Online: 82.22 Ns Ns
Brunner et al., 2011 Hybrid: SSVEP + P300 Moving both hand or both feet None 12 SSVEP: 2. MI: 3. LEDs flickering at 8 Hz (top) and LED at 13 Hz (bottom) logarithmic band power: SSVEP and ERD LDA ERD: 79.9 SSVEP: 98.1 Hybrid: 96.5 ERD: 3.2. SSVEP (6.1) hybrid (6.3) CV
Edlinger et al., 2011 Hybrid: SSVEP + P300 VR, control of virtual smart home environment None 3 SSVEP: 8. parietal/occipital. P300: 8 frontal, central occipital, parietal P300: rectangular matrix with characters or icons, flashed in a random order SSVEP: flickering lights (LEDs) or flickering symbols (5 -25 Hz) SSVEP: minimum energy (ME) algorithm, P300: NA P300: LDA, SSVEP: LDA P300: 100 NS NS
Su et al., 2011 Hybrid: P300 + MI VR None 4 P300: 14. MI: 22. NS P300: piecewise cubic spline interpolation+ Butterworth filter + average. MI: multiple band-pass filters P300: SVM, MI: FLDA Offline (MI): 92.5–100 NS NS
Sakurada et al., 2013 SSVEP + P300 Upper limb rehabilitation,. Occupational therapy 3 (upper cervical SCI) 12 SSVEP: 3 SSVEP: 3 LEDs flickering at 8 Hz (green and blue). P300: Flash matrix power spectrum (FFT) + CCA SVM Healthy: 88.46. Patients: 81.19 NS NS
Choi et al., 2016 SSVEP + MI FES, hand-wrist rehabilitation. SSVEP to stop FES None 4 MI: 3 central. SSVEP: 2 occipital. SSVEP: LED flickering at 9 Hz MI: ERD/ERS, SSVEP: averaged Pearson’s correlation (r-value) MI: FLDA SSVEP: CCA MI: 90.485 NS 10-fold CV
Yao et al., 2012 SSVEP FES, knee rehabilitation (movement training system) None 2 8 a red horizontal bar, flickering light at 6.82, 8.33 and 12.5 Hz Power spectrum LDA Online: 80.36–96.4 NS 10-fold CV
Duvinage et al., 2012 P300 Lower limb rehabilitation. Foot lifting orthosis None 5 32 NS xDAWN + two epochs average LDA 94.30 NS NS
Ortner et al., 2011 SSVEP Hand Orthosis None 7 1: O1 2 LEDS, flickering at 8 and 13 Hz PSD HSD 78 NS NS
Rohani et al., 2014 P300 VR None 5 4 NS NS SVM NS NS NS
Son et al., 2020 SSVEP FES, upper limb rehabilitation None 11 19 flickering action video at 15 Hz STFT, Power average CSP (discriminating 2 class) 93.51 NS 10-fold CV
Chen et al., 2019 High-frequency SSVEP Robotic arm None 10 9: parietal or occipital Flicker: 30, 31, 32, and 33 Hz Spectral amplitude FBCCA Online: 97.75 Online: 17 NS
Li et al., 2018 SSVEP Hand prosthesis None 6 2: occipital Scene graph paradigm -drinking & eating-, (8, 9.24, 10.9, and 12 Hz) Time-frequency spectra, STFT CCA 94.58 19.55 NS
Horki et al., 2011 SSVEP + MI Prosthesis: artificial upper limb, elbow control None 12 26: occipital and central 2 bars of red LEDs, flickering at 8 and 13 Hz Sequential floating forward selection CCA Offline: 91 NS 10-fold CV
Koo et al., 2015 SSVEP VR None 3 8: central, parietal and occipital Flickering lights at 5.5, 6.7, 7.5, and 8.6 Hz NS CCA for SSVEP detection 100 24.58 NS
Chu et al., 2018 SSVEP Robotic rehabilitation system None 6 14: frontal, parietal, occipital Three squares flashing at 12, 15, 20 Hz Power spectrum LDA (voting) 82.30 27.40 NS
Gui et al., 2015 SSVEP Lower limb rehabilitation system (hip and knee) None 6 4: occipital and parietal Flickering at 6.82, 7.5, 8.33, and 12.5 Hz Spectral amplitude LDA 92.40 NS NS
Huang et al., 2019 P300 VR None 6 32 3D stereo visual stimuli NS BLDA 96 42.51 10-fold CV
Yao et al., 2019 SSVEP VR None 10 9: parietal and occipital 2 stimulus presentation methods. 3D stimulus at 9, 10, 11, 12, 45 Hz NS FBCCA Static mode: 92 Static mode: 22.49 Leave one-out CV
Touyama and Sakuda, 2017 Collaborative SSVEP VR None 8 2: parieto-occipital two virtual cubes flickering at 6 and 8 Hz Spectral amplitude FLDA 95.2 NS NS
Bhattacharyya et al., 2014 P300 Robot arm control for prosthetics application None 5 1: Pz Oddball-like paradigm (Temporal) Average of 4 epochs SVM (linear kernel) Offline: 95.2. Online: 81.5 Online: 23.83 NS
Chen et al., 2018 SSVEP Robotic arm control None 12 10: P3, Pz, P4, PO3, PO4, T5, T6, O1, Oz, O2 15 targets (8–15 Hz in 0.5 Hz steps) FBCCA for EEG decomposition Ensemble Classifier Robotic movement task: 92.78 49.25 NS
Casey et al., 2019 P300 Robotic arm control None 4 6: Pz, P3, P4, PO3, PO4, and Oz P300 speller programmed to control a robotic arm Minimum and maximum amplitudes in the frequency domain (6 features per electrode) 2 classifiers: SVM (RBF kernel), and Random Forest 38.023 NS NS
Achanccaray et al., 2019 P300 Robotic arm Control None 8 16 Two images flashing randomly: a wheelchair and a robotic arm CSP BLDA Training: 91.6. Test: 82.6. NS NS
Ding-Guo and Ying, 2012 SSVEP FES, lower limb None 6 NS NS Frequency-domain LDA 85 NS NS
Huang et al., 2013 P300 Elbow rehabilitation robot None NS NS Panel with 25 commands NS SVM Online: 90.82 NS NS
Okahara et al., 2018 SSVEP Neuro-prosthesis 3-ALS NS 1: Oz 4 × 4 LED flicker at 32–54 Hz PSD Classification Threshold Online 83.3 NS NS
Xu et al., 2021 SSVEP Upper Limb Exoskeleton None 5 6: O1, O2, Oz, P3, Pz, P4 4 Flickering squares at 8.57, 10, 12, 15 Hz Frequency domain CCA Offline: 86.1 NS NS

BLDA, Bayesian linear discriminant analysis; CCA, canonical correlation analysis; CSP, common spatial patterns; DC, duty cycle; FLDA, Fisher’s Linear discriminant analysis; LDA, linear discriminant analysis; NS, non-specified; SVM, support vector machine; VR, virtual reality; CV, cross validation; FES, Functional Electrical Stimulation; MI, motor imagery; SSVEP, steady state visually evoked potentials; SCI, spinal cord injury; HSD, harmonic sum decision; STFT, short-time Fourier Transform.