Table 2.
Comparison of experimental and modelled (predicted) resonant frequency values for LoRa designs nominally at 433 MHz and 915 MHz. Prediction error shown indicating a rms error of 3.6% at 915 MHz and 1.3% at 433 MHz.
433 MHz Series | SRR Design 1 | SRR Design 2 | SRR Design 3 | SRR Design 4 | SRR Design 5 | rms | mean |
---|---|---|---|---|---|---|---|
Experimental | 413.6 | 457 | 373.4 | 427.8 | 413.9 | 30.2 | 417.1 |
Predicted | 437.5 | 481.2 | 393.7 | 440.5 | 439.7 | 31.0 | 438.5 |
Prediction error | 5.78% | 5.30% | 5.44% | 2.96% | 6.23% | 1.27% | 5.14% |
915 MHz Series | SRR Design 1 | SRR Design 2 | SRR Design 3 | SRR Design 4 | SRR Design 5 | rms | mean |
Experimental | 904.6 | 938.2 | 851.5 | 1032.4 | 856.8 | 73.9 | 916.7 |
Predicted | 927.3 | 972.5 | 880.6 | 1002.1 | 917.1 | 47.8 | 939.9 |
Prediction error | 2.51% | 3.65% | 3.41% | −2.94% | 7.04% | 3.61% | 2.74% |