Skip to main content
. 2021 Dec 1;21(23):8032. doi: 10.3390/s21238032

Table 4.

Estimation results for real cables with one capacitive fault.

Position of the Fault (m) Capacity of the Fault (pF) Length of the Cable (m)
Nominal Estimated Nominal Estimated Nominal Estimated
50 49.94 107 112 65 65.00
50 49.92 152 158 65 65.01
50 49.97 217 205 65 64.92
50 49.92 309 310 65 64.95
50 49.96 404 434 65 65.01
50 49.99 450 450 65 64.96