Skip to main content
. 2021 Dec 1;21(23):8032. doi: 10.3390/s21238032

Table 6.

Estimation results for real cables with three capacitive faults.

Experiment 1 Experiment 2
Nominal Estimated Nominal Estimated
Length of the Cable (m) 131 130.99 131 130.93
Position of Fault 1 (m) 50 49.90 50 49.93
Position of Fault 2 (m) 65 65.06 65 64.99
Position of Fault 3 (m) 115 115.09 115 114.92
Capacity of Fault 1 (pF) 107 115 217 214
Capacity of Fault 2 (pF) 217 210 450 454
Capacity of Fault 3 (pF) 404 431 404 418