Table 7.
Estimation results for real cables with four capacitive faults.
Experiment 1 | Experiment 2 | |||
---|---|---|---|---|
Nominal | Estimated | Nominal | Estimated | |
Length of the Cable (m) | 143 | 142.96 | 143 | 142.96 |
Position of Fault 1 (m) | 50 | 49.87 | 50 | 49.88 |
Position of Fault 2 (m) | 65 | 65.12 | 65 | 65.03 |
Position of Fault 3 (m) | 115 | 114.93 | 115 | 114.95 |
Position of Fault 4 (m) | 131 | 131.40 | 131 | 131.32 |
Capacity of Fault 1 (pF) | 107 | 117 | 107 | 115 |
Capacity of Fault 2 (pF) | 217 | 214 | 152 | 165 |
Capacity of Fault 3 (pF) | 404 | 436 | 309 | 323 |
Capacity of Fault 4 (pF) | 450 | 441 | 450 | 439 |