Table 3.
Accuracy of photogrammetric reconstruction for different degrees of blurring (Figure 8).
| 1 | 2 | 3 |
|---|---|---|
| ICP | ICP | |
| 3D surfaces | avg | stdev. |
| comparison | (mm) | (mm) |
| No blurring | 0.21 | 0.36 |
| 30 | 0.49 | 0.67 |
| 60 | 1.07 | 1.02 |
Accuracy of photogrammetric reconstruction for different degrees of blurring (Figure 8).
| 1 | 2 | 3 |
|---|---|---|
| ICP | ICP | |
| 3D surfaces | avg | stdev. |
| comparison | (mm) | (mm) |
| No blurring | 0.21 | 0.36 |
| 30 | 0.49 | 0.67 |
| 60 | 1.07 | 1.02 |