Table 1.

Disposal facilities Disposal capability (TPD) Treatment temperature Strengths Weaknesses
Movable incineration equipment 1–5 800–1100 °C
  • Can dispose of MW on site

  • Easy to install and operate

  • Small operation area

  • Can dispose of almost all kinds of MW

  • Small disposal capacity

  • Risk of emissions easily exceed the standard due to immature technology

Movable steam sterilization cabin 2–5 >134 °C
  • Can dispose of MW on site

  • Easy to install and operate

  • Small operation area

  • High automation degree

  • Small disposal capacity

  • Not suitable for pharmaceutical MW and chemical MW

Movable microwave sterilization equipment 3–10 >95 °C
  • Can dispose of MW on site

  • Easy to install and operate

  • Small operation area

  • High automation degree

  • Small disposal capacity

  • Not suitable for pharmaceutical MW, chemical MW and partial pathological MW (human limbs and organs)

MSW incineration facility 30–100 >850 °C
  • Large disposal capacity

  • Great potential in improving emergency disposal MW capability

  • Energy recovery by generating electricity

  • High infection risk due to MW transportation

  • Need equipment upgrade and transformation to adapt to MW

  • Higher content of hydrogen chloride and dioxins in the flue gas

  • Higher operating costs

  • Shorter equipment life

Hazardous waste incineration facility 2–60 >850 °C
  • Mature technology

  • Can dispose of almost all kinds of MW

  • High infection risk due to MW transportation

  • Need equipment upgrade and transformation to adapt to MW

  • Small potential in improving emergency disposal MW capability due to the small amount of facilities

  • Higher content of dioxins in the flue gas

Cement kiln 1–12 >1000 °C
  • Can be utilized as an alternative fuel

  • Large potential in improving emergency disposal MW capability

  • High infection risk due to MW transportation

  • Need equipment upgrade and transformation to adapt to MW

  • Higher content of dioxins in the flue gas