Table 7.
All undertaken classifiers’ accuracy for blade fault diagnosis classification.
Method | Accuracy | ||
---|---|---|---|
Train (%) | Validation (%) | Test (%) | |
Grayscale image + CNN | 96.32 | 88.63 | 83.49 |
CWT scalogram + CNN | 99.30 | 96.83 | 94.35 |
EEMD scalogram + CNN | 99.64 | 97.33 | 94.66 |
CEEMD scalogram + CNN | 99.67 | 97.59 | 95.37 |
NEEEMD scalogram + CNN | 99.42 | 97.84 | 96.31 |