Table 3.
Paper and system description | Device location | System type | System metrics (hand hygiene opportunities) | |||||
Electronic dispenser | ||||||||
|
Arai et al [44] | |||||||
|
|
Dispenser | Outpatient area | Commercial (Compleo-IO) | Outpatient visit records | |||
|
Asai et al [45] | |||||||
|
|
Dispenser | Hospital entrance | Research | Hand hygiene events | |||
|
Boyce et al [46] | |||||||
|
|
Dispenser | Patient room and hallway | Commercial (iSIGNOL) | Hand hygiene events | |||
|
Cohen et al [47] | |||||||
|
|
Dispenser | Throughout entire facility | Commercial (DebMed GMS) | Hand hygiene events | |||
|
Conway et al [48] | |||||||
|
|
Dispenser | Throughout entire facility | N/Aa | Expected hand hygiene events | |||
|
Diefenbacher et al [50] | |||||||
|
|
Dispenser | Patient room | Commercial (Ingo-man Weco) | Hand hygiene events (conversion factor) | |||
|
Helder et al [54] | |||||||
|
|
Dispenser | Patient room | Commercial (ComSens NewCompliance) | Hand hygiene events | |||
|
Kato et al [55] | |||||||
|
|
Dispenser | Outpatient area | Commercial (CARECOM Co, Ltd) | Outpatient visit records | |||
|
Morgan et al [59] | |||||||
|
|
Dispenser | Patient room | N/A | Patients number | |||
|
De MacEdo et al [49] | |||||||
|
|
Dispenser | Patient room | Commercial (NXT 1-L model) | Nurse visits (nurse call system) | |||
|
Marra et al [56,67], Magnus et al [32], and Sodré da Costa et al [33] | |||||||
|
|
Dispenser | Patient room | Commercial (NXT 1-L model) | Hand hygiene events | |||
|
Scheithauer et al [57] | |||||||
|
|
Dispenser | Throughout entire facility | Commercial (Ingo-man Weco) | Documented activities | |||
Electronic dispenser assisted by other sensors | ||||||||
|
Ellison et al [51] | |||||||
|
|
Dispenser | Throughout intensive care units | N/A | Patient room entry/exit events | |||
|
|
Motion sensor | Patient room entrance | N/A | Patient room entry/exit events | |||
|
Sharma et al [61] | |||||||
|
|
Dispenser | Hallway | Research | Patient room entry/exit events | |||
|
|
Motion sensor | Examination room entrance | Research | Patient room entry/exit events | |||
|
Gaube et al [66] | |||||||
|
|
Dispenser | Patient room and hallway | Research | Patient room entry/exit events | |||
|
|
Motion sensor | Dispenser | Research | Patient room entry/exit events | |||
|
Geilleit et al [53] | |||||||
|
|
Dispenser | Examination room | Research | Patient room entry/exit events | |||
|
|
Motion sensor | HCWs’b work area | Research | Patient room entry/exit events | |||
|
|
Pressure plate | Examination couch, Chair | Research | Patient room entry/exit events | |||
|
Galluzzi et al [52,68] | |||||||
|
|
Dispenser | N/A | Research | Hand hygiene events | |||
|
|
IMUc | HCWs (wristwatch) | Research | Hand hygiene events | |||
|
Tobita et al [62] | |||||||
|
|
Dispenser | Sink | Research | Hand hygiene events | |||
|
|
Microphone | Sink | Research | Hand hygiene events | |||
IMU and microphone | ||||||||
|
Uddin et al [63] | |||||||
|
|
IMU | HCWs (wristband) | Research | Hand hygiene events | |||
|
Li et al [69] | |||||||
|
|
IMU | HCWs (wristband) | Research | Hand hygiene events | |||
|
Ram et al [60] | |||||||
|
|
IMU | Soap bar | Research | Hand hygiene events | |||
|
Wright et al [64] and Zillmer et al [65] | |||||||
|
|
IMU | Soap bar | Research | Hand hygiene events | |||
|
|
Microphone | Soap bar | Research | Hand hygiene events | |||
|
Wijayasingha et al [70] | |||||||
|
|
IMU | HCWs (wristwatch) | Research | Hand hygiene events | |||
|
|
Microphone | HCWs (wristwatch) | Research | Hand hygiene events | |||
|
Miyazaki et al [58] | |||||||
|
|
Microphone | Sink | Research | Hand hygiene events |
aN/A: not applicable.
bHCW: health care worker.
cIMU: inertial measurement unit.