Skip to main content
. 2021 Nov 18;36(48):e328. doi: 10.3346/jkms.2021.36.e328

Table 5. Discordant results of SARS-CoV-2 between the three commercial kits.

Specimen No. Interpretations and Ct values of target genes
PowerChek STANDARD M Allplex
Interpr. E ORF1ab Interpr. E ORF1ab Interpr. N RdRp S
6 P 33.8 37.5 P 34.4 30.5 I - 34.7 32.8
36 I 35.8 - P 34.0 33.1 I - 35.3 34.0
65 I 36.7 - I 36.4 35.1 P 35.2 35.7 36.0
66 I 38.3 35.1 N - 36.4 P 34.9 31.7 32.3
67 P 36.0 37.6 I - 33.5 P 35.7 34.8 34.9
72 I - 37.2 P 35.3 33.4 P 34.7 36.8 36.0
75 P 36.8 36.7 I - 33.1 I 35.2 36.2 -
80 N - - P 33.9 31.0 P 34.1 32.5 31.4
94 I 35.1 38.1 P 33.3 32.6 P 33.4 33.6 32.5
97 N 38.7 38.3 P 34.8 34.7 I - 35.4 36.1

All specimens were derived from coronavirus disease 2019 confirmed cases.