TABLE III.

A Comprehensive Summary of the Evaluation Results. For MBF Bias, * Indicates the Results’ Mean Is Significantly Different From Zero Based on Paired t-Test (5% Significance Level). Bold Font Indicates the Best Performer in Each Group

Error Type Method Square
Motion(200)
Triangle
Motion(200)
Spike
Motion (200)
Mean Motion Error (mm) NoMC 4.6±1.7 2.6±1.0 4.7±1.3
MC-IR 6.4±2.2 6.4±2.2 6.4±2.1
MC-CR 4.6±1.0 4.7±0.9 4.5±0.9
MC-CNN 1.8±0.8 1.6±0.7 1.7±0.7
MC-CNN-C 4.4±3.0 3.0±1.5 4.7±2.6
DeepMC 1.0±0.6 0.9±0.5 0.8±0.4
Max Motion Error (mm) NoMC 13.3±3.7 12.8±3.7 18.4±1.8
MC-IR 46.7±19.7 46.4±19.9 46.2±19.2
MC-CR 11.7±2.6 11.8±2.5 11.7±2.4
MC-CNN 5.5±2.5 5.3±2.5 5.9±2.4
MC-CNN-C 10.1±5.9 8.2±3.7 10.7±5.6
DeepMC 3.6±2.0 3.2±1.9 3.6±1.9
MBF Bias (%) NoMC −9.8±33.0%* −7.4±16.2%* −4.0±17.3%*
MC-IR 62.3±51.3%* 62.1±52.0%* 64.8±53.1%*
MC-CR 6.0±7.4%* 5.9±7.3%* 6.1±6.9%*
MC-CNN 1.2±5.9* 1.7±5.7* 2.2±5.6*
MC-CNN-C −2.3±10.4* −2.8±12.5* −3.0±10.6*
DeepMC −0.5±4.6% −0.1±3.9% 0.4±3.6%
Fitting Residuals (Bq/mL×min2) NoMC 1.43×10−3 9.54×10−4 2.16×10−3
MC-IR 6.04×10−3 6.00×10−3 6.22×10−3
MC-CR 1.81×10−3 1.77×10−3 1.81×10−3
MC-CNN 3.33×10−3 2.92×10−3 3.11×10−3
MC-CNN-C 7.47×10−4 7.82×10−4 7.93×10−4
DeepMC 6.29×10−4 6.06×10−4 6.24×10−4
Motion Free 6.20×10−4 6.20×10−4 6.20×10−4