Corkum 2018.
Study characteristics | |||
Patient Sampling | Type of study: retrospective | ||
Patient characteristics and setting | Sample size: 135 Females: unclear Mean age: 11.5 Inclusion criteria: children aged 5 to 18 with suspected appendicitis undergoing USS Exclusion criteria: no absolute neutrophil count available Setting: university hospital, USA, 2015 to 2016 |
||
Index tests | Index test: MRI Index test criteria for positive diagnosis: see Appendix 5 |
||
Target condition and reference standard(s) | Target condition: appendicitis Reference standard: histology or follow‐up |
||
Flow and timing | Type and length of follow‐up: 30‐day readmission data Number of participants who were excluded from the analysis: 16/128 (12.5%) |
||
Comparative | |||
Notes | |||
Methodological quality | |||
Item | Authors' judgement | Risk of bias | Applicability concerns |
DOMAIN 1: Patient Selection | |||
Was a consecutive or random sample of patients enrolled? | Yes | ||
Avoids Inappropriate Exclusion | Unclear | ||
Could the selection of patients have introduced bias? | Unclear risk | ||
Are there concerns that the included patients and setting do not match the review question? | Low concern | ||
DOMAIN 2: Index Test (All tests) | |||
Were the index test results interpreted without knowledge of the results of the reference standard? | Yes | ||
If a threshold was used, was it pre‐specified? | Unclear | ||
Could the conduct or interpretation of the index test have introduced bias? | Unclear risk | ||
Are there concerns that the index test, its conduct, or interpretation differ from the review question? | High | ||
DOMAIN 3: Reference Standard | |||
Are the reference standards (histo or F/U) likely to correctly classify the target condition? | No | ||
Were the reference standard (histo or F/U) results interpreted without knowledge of the results of the index test | Unclear | ||
Could the reference standard, its conduct, or its interpretation have introduced bias? | High risk | ||
Are there concerns that the target condition as defined by the reference standard does not match the question? | Low concern | ||
DOMAIN 4: Flow and Timing | |||
Did all patients receive the same reference standard? | No | ||
Were all patients included in the analysis? | Yes | ||
>95% histo or F/U | Yes | ||
all +ve MRI had surgery or F/U | Yes | ||
all ‐ve MRI had surgery or F/U | Unclear | ||
choice of reference standard independent of MRI | No | ||
Could the patient flow have introduced bias? | High risk |