Patel 2017.
Study characteristics | |||
Patient Sampling | Type of study: retrospective | ||
Patient characteristics and setting | Sample size: 42 Females: 42 Mean age: 25.5 Inclusion criteria: pregnant women with suspected appendicitis Exclusion criteria: patients with MRI performed at an outside hospital Setting: university teaching hospital, USA, 2008 to 2015 |
||
Index tests | Index test: MRI Index test criteria for positive diagnosis: see Appendix 5 |
||
Target condition and reference standard(s) | Target condition: appendicitis Reference standard: histology or follow‐up |
||
Flow and timing | Type and length of follow‐up: chart review up to 6 months postdischarge Number of participants who were excluded from the analysis: unclear |
||
Comparative | |||
Notes | |||
Methodological quality | |||
Item | Authors' judgement | Risk of bias | Applicability concerns |
DOMAIN 1: Patient Selection | |||
Was a consecutive or random sample of patients enrolled? | Unclear | ||
Avoids Inappropriate Exclusion | Unclear | ||
Could the selection of patients have introduced bias? | Unclear risk | ||
Are there concerns that the included patients and setting do not match the review question? | Low concern | ||
DOMAIN 2: Index Test (All tests) | |||
Were the index test results interpreted without knowledge of the results of the reference standard? | Unclear | ||
If a threshold was used, was it pre‐specified? | No | ||
Could the conduct or interpretation of the index test have introduced bias? | High risk | ||
Are there concerns that the index test, its conduct, or interpretation differ from the review question? | Low concern | ||
DOMAIN 3: Reference Standard | |||
Are the reference standards (histo or F/U) likely to correctly classify the target condition? | No | ||
Were the reference standard (histo or F/U) results interpreted without knowledge of the results of the index test | Yes | ||
Could the reference standard, its conduct, or its interpretation have introduced bias? | High risk | ||
Are there concerns that the target condition as defined by the reference standard does not match the question? | Low concern | ||
DOMAIN 4: Flow and Timing | |||
Did all patients receive the same reference standard? | No | ||
Were all patients included in the analysis? | Yes | ||
>95% histo or F/U | Yes | ||
all +ve MRI had surgery or F/U | Yes | ||
all ‐ve MRI had surgery or F/U | Yes | ||
choice of reference standard independent of MRI | No | ||
Could the patient flow have introduced bias? | High risk |