Skip to main content
. 2021 Dec 10;2(4):100998. doi: 10.1016/j.xpro.2021.100998
Reagent Final concentration Amount
G-418 50 mg/mL 500 mg
MiliQ H20 n/a 10 mL
Total n/a 10 mL

Filter sterilize using a 10 mL syringe equipped with 0.22 μm filter, store at −20°C for up to one year.