Skip to main content
. Author manuscript; available in PMC: 2022 Nov 1.
Published in final edited form as: Circ Cardiovasc Interv. 2021 Oct 22;14(11):e011028. doi: 10.1161/CIRCINTERVENTIONS.121.011028

Table 2:

BASILICA Valve Data

Valve FailureMode Prior Valve Type New THV Valve nominalSize
Patient Number
1 AS 23 Perimount S3 23
2 AS 21 Mitroflow S3 20
3 AS 19 Trifecta S3 20
4 AS 23 Trifecta S3 23
5* AI 27 Freestyle S3 23
6 AI 23 Trifecta S3 23
7* AI 21 Mitroflow S3 20
8 AS 29 Corevalve S3 26
9 AS 29 Sapien3 S3 29
10 AS 27 Magna EvolutPro + 29
11 AI 25 Toronto S3 23
12 AS 29 EvolutR S3 Ultra 23
13 AI 29 Mitroflow S3 Ultra 26
14 AS 21 Magna EvolutPro + 23
15* AI 19 Mitroflow S3 20
16 AS 26 EvolutR S3 23

A table summarizing clinical data from all BA-BASILICA patients. Bold text denotes patients requiring coronary stenting, despite BASILICA.

*

denotes patients requiring coronary stenting, despite BASILICA

Abbreviations: AI – aortic insufficiency, AS – aortic stenosis, S3 – Sapien3, THV - transcatheter heart valve