Skip to main content
. 2000 Jun;38(6):2097–2102. doi: 10.1128/jcm.38.6.2097-2102.2000

TABLE 10.

Comparison of “best” European immunoblot interpretation rule with best rule for individual laboratories

Laboratory Strain European rule no. European rule % Sens/% spec for European rulea Individual laboratory rule % Sens/% spec for individual laboratory rulea
A ACA1 5 3 bands from p41 (M)b, OspC (M), p83/100, p39, p41, p17 80/94 19 alone or 2 bands from p58, OspC (M), p41 (M) 80/92
B ESP1 2 2 bands from p41 (M), OspC (M), p83/100, p58, p39 81/94 2 bands from p39, OspC, OspC (M), p21 85/98
C A395 6 3 bands fsrom p41 (M), OspC (M), p83/100, p39, p17, OspC 56/99 2 bands from p34, OspC(M), p21, p41 73/97
D PKo 7 2 bands from p41 (M), OspC (M), p83/100, p39, p41, p17, OspC 83/92 p41 and p43, or p58, or p14, or OspC(M) 83/95
D PBi 5 2 bands from p41 (M), OspC (M), p83/100, p39, p41, p17 74/89 p58, or OspC (M), or p21, or p30 79/93
E VS461 4 3 bands from p41 (M), OspC (M), p83/100, p39, p17 67/97 3 bands from p58, p39, p28, p83/100, p41 (M), p60 (M) 78/96
F Ne83 6 3 bands from p41 (M), OspC (M), p83/100, p39, p17, OspC 78/87 3 bands from p43, p54/55, p41, OspC (M), p41 (M) 80/96
a

Sens, sensitivity; spec, specificity. Sensitivity calculated by combining data for patient with EM and LB. Specificity was calculated by combining data for potential cross-reactor and healthy individuals' sera. 

b

M, IgM.