Skip to main content
. Author manuscript; available in PMC: 2021 Dec 16.
Published in final edited form as: Med Image Comput Comput Assist Interv. 2021 Sep 21;12904:478–487. doi: 10.1007/978-3-030-87202-1_46

Table 1.

RMSE (mean ± SD, unit: mm) of landmark localization.

Method AT PM FM SM CI MDR
Point++ 0.71 ± 0.49 1.02 ± 0.58 1.40 ± 0.53 1.44 ± 0.64 0.95 ± 0.61 17%
PointConv 0.66 ± 0.41 1.40 ± 0.54 1.39 ± 0.48 1.41 ± 0.58 0.82 ± 0.52 15%
MeshSegNet 0.64 ± 0.49 0.52 ± 0.41 0.59 ± 0.47 0.78 ± 0.43 0.78 ± 0.43 10%
DLL-SA 0.48 ± 0.27 0.51 ± 0.42 0.57 ± 0.48 0.69 ± 0.58 0.49 ± 0.38 3%
DLL-C 0.49 ± 0.29 0.48 ± 0.34 0.56 ± 0.41 0.60 ± 0.42 0.48 ± 0.34 10%
DLL-CS 0.40 ± 0.21 0.45 ± 0.32 0.51 ± 0.36 0.58 ± 0.39 0.42 ± 0.29 8%
DLLNet 0.30 ± 0.11 0.39 ± 0.26 0.47 ± 0.28 0.49 ± 0.37 0.28 ± 0.15 0%