TABLE 4. Comparison of the Performance Our Proposed Model With That of DarkCovidNet [19] on Both Datasets.
| Model | Test dataset | Normal | Pneumonia | COVID-19 |
|---|---|---|---|---|
| DL-CRC | Dataset used in our paper | 99.45% | 84.84% | 83.04% |
| Dataset in DarkCovidNet paper | 93%.00 | 6.00% | 80.00% | |
| DarkCovidNet | Dataset used in our paper | 13.33% | 82.94% | 45.00% |
| Dataset in DarkCovidNet paper | 84.00% | 80.00% | 76.00% |