Skip to main content
. 2021 Winter;21(4):341–346. doi: 10.31486/toj.20.0160

Table 2.

Comparison of Preimplant and Preexplant Echocardiographic Parameters, n=7

Echocardiographic Parameter Preimplant, Mean ± SD Preexplant, Mean ± SD P Value
Heart rate, min 91.7 ± 16.4 69.6 ± 8.9 0.01
Left ventricular ejection fraction, % 12.8 ± 6.9 52.8 ± 8.1 0.0001
Left ventricular end-diastolic internal diameter, mm 60.4 ± 11.7 42.6 ± 5.7 0.02
Left ventricular end-systolic internal diameter, mm 53.4 ± 14.3 33.4 ± 6.2 0.02
Base right ventricular internal diastolic diameter, mm 39.5 ± 6.2 34.8 ± 5.0 0.045
Mid right ventricular internal diastolic diameter, mm 24.3 ± 7.4 18.6 ± 5.6 0.03
Longitudinal right ventricular internal diastolic diameter, mm 77.6 ± 3.7 68.8 ± 5.8 0.006

Note: P<0.05 is statistically significant.