Skip to main content
. 2000 Jun;38(6):2227–2231. doi: 10.1128/jcm.38.6.2227-2231.2000

TABLE 3.

Sensitivities and specificities of the seven serological tests

Test No. positive (% sensitivity) among those with active tuberculosis (n = 44) No. negative (% specificity)
Mantoux test controls (n = 204) Anonymous controls (n = 50)
ICT Tuberculosis 18 (41) 195 (96) 44 (88)
RAPID TEST TB 11 (25) 178 (87) 43 (86)
TUBERCULOSIS IgA EIA 25 (57) 190 (93) 31 (62)
PATHOZYME-TB complex 7 (16) 197 (97) 48 (96)
PATHOZYME-MYCO IgG 24 (55) 182 (89) 45 (90)
PATHOZYME-MYCO IgA 18 (41) 174 (85) 36 (72)
PATHOZYME-MYCO IgM 8 (18) 164 (80) 50 (100)