Ferreira 2008.
Study characteristics | |||
Patient Sampling | Method of sampling: selected Included conditions: no cavitation and early lesions Teeth: primary and permanent, incisors and molars Sealants: no Surface: smooth |
||
Patient characteristics and setting | Age: 7 to 12 years Sex: not reported Ethnicity: not reported Country: Brazil Setting: school based Number of participants/teeth/sites: 36 participants Prevalence: not reported |
||
Index tests | Category of test: DIAGNOdent Sequence of test(s): index tests (DIAGNOdent) followed by reference standard (visual) Examiner training and calibration: yes Teeth cleaning prior to examination: professionally cleaned Tooth drying prior to examination: air dried 15 seconds Threshold applied: 0‐4 sound or outer enamel, 5‐10 inner enamel,10+ dentine Device specifics: tip B |
||
Target condition and reference standard(s) | Category: visual Sequence of index test and reference standard: reference standard then index test Training of examiner: unclear Blinding to index test: no Multiple tests: no Site selection: unclear Target condition: healthy, activity with intact surfaces, inactivity |
||
Flow and timing | Participants with index test but no reference standard: 0 Participants with reference standard but no index test: 0 Time interval between tests: minimal Participants receiving both tests but excluded from results: 0 |
||
Comparative | |||
Notes | |||
Methodological quality | |||
Item | Authors' judgement | Risk of bias | Applicability concerns |
DOMAIN 1: Patient Selection | |||
Was a consecutive or random sample of patients enrolled? | No | ||
Was a case‐control design avoided? | Yes | ||
Did the study avoid inappropriate exclusions? | Yes | ||
Could the selection of patients have introduced bias? | High risk | ||
Are there concerns that the included patients and setting do not match the review question? | Unclear | ||
DOMAIN 2: Index Test (All) | |||
Were the index test results interpreted without knowledge of the results of the reference standard? | Yes | ||
If a threshold was used, was it pre‐specified? | Yes | ||
If multiple tests were applied were different examiners used for each (in vivo)? | |||
Could the conduct or interpretation of the index test have introduced bias? | Low risk | ||
Are there concerns that the index test, its conduct, or interpretation differ from the review question? | Low concern | ||
DOMAIN 2: Index Test (Green fluorescence) | |||
DOMAIN 2: Index Test (Blue fluorescence) | |||
DOMAIN 2: Index Test (Red fluorescence) | |||
Were the index test results interpreted without knowledge of the results of the reference standard? | Yes | ||
If a threshold was used, was it pre‐specified? | Yes | ||
If multiple tests were applied were different examiners used for each (in vivo)? | |||
Could the conduct or interpretation of the index test have introduced bias? | Low risk | ||
Are there concerns that the index test, its conduct, or interpretation differ from the review question? | Low concern | ||
DOMAIN 3: Reference Standard | |||
Is the reference standards likely to correctly classify the target condition? | No | ||
Were the reference standard results interpreted without knowledge of the results of the index tests? | No | ||
Could the reference standard, its conduct, or its interpretation have introduced bias? | High risk | ||
Are there concerns that the target condition as defined by the reference standard does not match the question? | High | ||
DOMAIN 4: Flow and Timing | |||
Was there an appropriate interval between index test and reference standard? | Yes | ||
Did all patients receive the same reference standard? | Yes | ||
Were all patients included in the analysis? | Yes | ||
Could the patient flow have introduced bias? | Low risk |