Table 1.
Values of the parameters ai and Li used in the initial dose assessment to estimate the variation of the exposure rate with time in eqn (3) (Henderson 1991; Beck et al. 2022).
| i | ai | Li (h–1) |
|---|---|---|
| 1 | 1.033 × 102 | X–1.838 × 100 |
| 2 | 3.206 × 101 | X–6.369 × 10X–1 |
| 3 | 2.476 × 100 | X–1.189 × 10X–1 |
| 4 | 3.476 × 10X–1 | X–3.075 × 10X–2 |
| 5 | 1.332 × 10X–1 | X–8.284 × 10X–3 |
| 6 | 2.851 × 10X–2 | X–2.208 × 10X–3 |
| 7 | 3.302 × 10X–3 | X–4.653 × 10X–4 |
| 8 | 9.055 × 10X–5 | X–8.166 × 10X–5 |
| 9 | 3.692 × 10X–6 | X–2.312 × 10X–5 |
| 10 | 1.003 × 10X–5 | X–2.649 × 10X–6 |