Skip to main content
. Author manuscript; available in PMC: 2023 Feb 1.
Published in final edited form as: J Biomed Mater Res B Appl Biomater. 2021 Jul 21;110(2):422–430. doi: 10.1002/jbm.b.34918

TABLE 2.

aPTT, thromboelastography parameters and mean fibrin fiber diameter for the various compositions, negative control and positive control (Arista)

Composition aPTT (SD) (% control) R (SD) (min) Angle α (SD) (degrees) Maximum amplitude (SD) (mm) G (SD) (Kd cm−2) CI (SD) (a.u.) Mean fibrin fiber diameter (SD) (nm)
Control 100 (8.8)a 1.8 (0.2)a 82.3 (1.3)a 50.9 (1.7)a 5.2 (0.3)a 3.2 (0.2)a 112 (22)a
Arista 41.9 (17.9)b 1.6 (0.2)ab 83.1 (1.9)b 51.4 (1.9)a 5.3 (0.4)a 3.4 (0.3)a 134 (33)a
L 0 46.6 (14.7)b 1.4 (0.3)b 84.0 (1.7)bc 61.8 (1.5)bc 8.1 (0.5)bc 4.8 (0.1)b 85 (17)b
LTA2.5 33.3 (5.6)b 1.1 (0.1)b 83.9 (1.5)bc 64.9 (0.7)c 9.2 (0.3)d 5.5 (0.1)c 63 (15)c
LTA4 33.7 (7.1)b 1.3 (0.1)b 84.9 (0.5)c 63.9 (0.5)bc 8.8 (0.2)cd 5.3 (0.1)bc 64 (18)d
LTA5 34.2 (8.4)b 1.4 (0.2)b 84.4 (0.6)bc 60.4 (0.6)b 7.6 (0.2)b 4.8 (0.2)b 70 (16)d

Note: Identical letters denote no statistically significant difference at the p = .05 level.

Abbreviations: aPTT, activated partial thromboplastin time; CI, coagulation index.