Figure 7.

Figure 7.

Schematic representation of a swelling hydrogel microneedle array for transdermal drug delivery. Responsive hydrogels can be used to fabricate microneedle array systems for transdermal delivery of drugs (A). Upon the application of the stimulus, the swelling of the hydrogel microneedles allows the diffusion of drugs to epidermis and dermis, bypassing the stratum corneum and promoting absorption to blood stream (B)