Skip to main content
. 2021 Dec 15;21(87):e271–e276. doi: 10.15557/JoU.2021.0046

Tab. 4.

Receiver operating characteristic of different cut-off at lung ultrasound score for diagnosis of COVID-19 associated pneumonia

Lung ultrasound score Se, % 95% CI Sp, % 95% CI PPV, % NPV, %
≥0 100.00 86.3-100.0 0.00 0.0-23.2 64.1
>0 100.00 86.3-100.0 57.14 28.9-82.3 80.6 100.0
>1 96.00 79.6-99.9 64.29 35.1-87.2 82.8 90.0
>2 88.00 68.8-97.5 100.00 76.8-100.0 100.0 82.4