Table 3.

Effect of central automated unit dose dispensing and barcode-assisted medication administration on medication administration errors (MAEs)

Mixed-effects logistic regression analysisa
MAE prevalence Univariable analysis N = 3097 Multivariable analysisb N = 3095 Multivariable analysis with nurse characteristicsc N = 1561
Measurement period n/N (%) OR (95% CI) Adjusted OR (95% CI) Adjusted OR (95% CI)
Pre-intervention 291/1490 (19.5) Reference Reference Reference
Post-intervention 258/1630 (15.8) 0.76 (0.55–1.04) 0.70 (0.51–0.96)* 0.57 (0.37–0.88)*

CI, confidence interval; OR, odds ratio.

a

Mixed-effects logistic regression analysis was used to account for within-subject correlations due to repeated measurements by staff member and patient.

b

ORs have been adjusted for pharmaceutical form, time window and clinical ward type.

c

ORs have been adjusted for nurse educational level, nurse degree type, pharmaceutical form, time window and clinical ward type.

*

Statistically significant (P < 0.05).