Table 2.

Recovery Experiments of Dual LFIA for Detection of Salmonella and E. coli O157:H7 Spiked in Milk and Ice Cream

detected (cfu/mL)
added (cfu/mL)
found (cfu/mL)
recovery (%)
sample Salmonella E. coli O157:H7 Salmonella E. coli O157:H7 Salmonella E. coli O157:H7 Salmonella E. coli O157:H7
milk 0 0 1 × 102 1 × 102 92 117 92.00 117.00
milk 0 0 1 × 103 1 × 103 1088 942 108.80 94.20
milk 0 0 1 × 104 1 × 104 10 664 10 396 106.64 103.96
milk 0 0 1 × 105 1 × 105 107 468 91438 107.47 91.44
ice cream 0 0 1 × 102 1 × 102 96 109 96.00 109.00
ice cream 0 0 1 × 103 1 × 103 1136 929 113.60 92.90
ice cream 0 0 1 × 104 1 × 104 10 817 10 718 108.17 107.18
ice cream 0 0 1 × 105 1 × 105 93 253 109 562 93.25 109.56