Skip to main content
. 2021 Dec 17;11:24175. doi: 10.1038/s41598-021-03447-w

Table 2.

Experimental considerations, materials, and average degradation rate of W, Ni0,8Cr0,2 and stainless steel.

Material D (µm) Number assays Δ V (kV) Exposure time, tf (h) Corona power reduction (%) Final state Final current, I (µA/cm) Qf (C/cm) ea (µg/C)
Stainless steel 302 50 12 4.75 50 72.7 Rupture 15 4 29
Ni0.8Cr0.2 50 8 4.75 95 48 Rupture 32.5 11.1 7.6
Tungsten 50 18 4.5–4.75 1630 56.5 Stopped 50 300.42 0.92
25 8 4–4.3 450 40.3 Stopped 27.5 44.5 3.7
100 10 4.9–5.2 600 65.2 Stopped 40 86.4 5.3