Skip to main content
. 2022 Jan;158:107005. doi: 10.1016/j.envint.2021.107005

Table 4.

Comparison of inter-rater agreement ratings for Version 4.0 versus Version 6.0 of RoB-SPEO by domain.

RoB-SPEO domain Inter-rater reliability, Version 4.0 Inter-rater reliability, Version 6.0 Change from Version 4.0 to Version 6.0
1 Bias in selection of participants into the study 0.33 0.67 +0.34
2 Bias due to a lack of blinding of study personnel 0.65 0.82 +0.17
3 Bias due to exposure misclassification 0.76 0.80 +0.04
4 Bias due to incomplete exposure data 0.31 0.73 +0.42
5 Bias due to selective reporting of exposures 0.80 0.82 +0.02
6 Bias due to conflict of interest 0.51 0.76 +0.25
7 Bias due to differences in numerator and denominator NAa 0.54 NAa
8 Other bias 0.51 0.74 +0.23
a

NA = not applicable (the domain of bias due to differences in numerator and denominator was not included in Version 4.0 of RoB-SPEO).