Table 3.

Primary and secondary outcomes of patients by use of preclosure device

Outcome All subjects Preclosure used Surgical removal P value
Primary outcome
 Limb complications 15 (15.2) 3 (5.9) 12 (25.0) .011
Components of primary outcome
 Limb ischemia 7 (7.1) 2 (3.9) 5 (10.4) .259
 Infection at removal site 8 (8.1) 1 (2.0) 7 (14.6) .028
 Removal site necrosis 2 (2.0) 0 2 (4.2) .233
Secondary outcomes
 Bleeding event 14 (14.1) 3 (5.9) 11 (22.9) .020
 Pseudoaneurysm 0 0 0
 Distal part embolization 1 (1.0) 0 1 (2.1) .485
 ICU length of stay after decannulation (d) 9 (5, 17) 8 (5, 17) 9 (5, 20) .725

Values are presented as median (25th percentile, 75th percentile) or n (%). ICU, Intensive care unit.