Skip to main content
. 2022 Jan 1;51(1):20200323. doi: 10.1259/dmfr.20200323

Table 5.

Radiographic and physical properties for samples of PMC-780 Dry polyurethane rubber and epoxy containing various amounts of glass bubbles

Modified PMC-780 Dry polyurethane rubber Modified epoxy resin
Glass bubbles percent by mass of urethane Density [g/cm3] Average measured HU (SD) Glass bubble percent by mass of epoxy Average measured HU (SD)
0.0 1.06 38 (9.5) 0.0 182 (6.1)
2.5 0.96 −63 (11) 2.0 100 (7.2)
3.5 0.92 −114 (8.0) 3.0 28 (7.2)
5.0 0.88 −133 (9.2) 4.0 24 (6.5)
7.5 0.81 −193 (10) 6.0 −50 (7.5)
10 0.76 −246 (8.8) 8.0 −130 (6.8)
10 −175 (13)

HU, Hounsfield unit; SD, standard deviation.

HUs were measured using a clinical CT scanner (Somatom Definition Edge, Siemens) with 0.75 mm slice thickness, 120 kV tube potential, 350 mAs, reconstructed with B40s medium kernel.