Skip to main content
. 2021 Dec 9;12:799910. doi: 10.3389/fimmu.2021.799910

Table 2.

Percentage of double-positive cells of three donors, stained with CD4-Nb1 or CD4-Nb2 (100 nM), or CD4-Nb3 or CD4-Nb4 (1,000 nM), compared to anti-CD4 antibody and negative control Nb (GFP-Nb, 1,000 nM).

Frequency CD3+ CD4+ (%)
c (nM) Donor 1 Donor 2 Donor 3
Anti-CD4 antibody ~1 33.7 27.0 24.3
CD4-Nb1 100 30.5 29.2 22.7
CD4-Nb2 100 33.8 25.6 18.4
CD4-Nb3 1,000 35.5 26.5 20.4
CD4-Nb4 1,000 33.8 26.9 23.9
GFP-Nb 1,000 1.4 0.3 1.0