Skip to main content
. 2021 Mar 31;11(21):12649–12657. doi: 10.1039/d1ra01572a

INZ determination in real samples (urine and human serum) by proposed SWASV technique.

Sample Analyte INZ conc. added (μM) INZ conc. detected (μM) Recovery (%) RSD (%) (n = 3)
Urine INZ 5 4.94 98.8 2.5
Human serum INZ 2 1.96 98.0 3.4