Electrochemical response characteristics of the proposed sensor.
Parameter | Responsea | |
---|---|---|
Concentration range (M) | 1.00 × 10−2 to 6.00 × 10−6 | |
Linearity | Slope (mV per decade) | 58.86 |
Intercept (mV) | 549.78 | |
Correlation coefficient | 0.9985 | |
Accuracy (mean ± SD) | 101.59 ± 0.971 | |
Precision | Repeatabilityb (% RSD) | ±1.574 |
Intermediate precisionc (% RSD) | ±2.119 | |
LODd (M) | 3.60 × 10−6 M | |
Response time (s) | 8 | |
Working pH range | 2–10 | |
Stability (days) | 30 |
Average of five determinations.
The intraday (n = 3), an average of three different concentrations repeated three times within the day.
The interday (n = 3), an average of three different concentrations repeated three times in three successive days.
Limit of detection calculated according to the IUPAC recommendations.