Skip to main content
. 2021 Dec 10;9:779946. doi: 10.3389/fbioe.2021.779946

TABLE 1.

Goodness of fit of the viscous (Crisco et al., 2007) and boundary (Stanton, 1923) friction model to the recorded flexion-extension data under swing and stance phase loading conditions and the meniscus states intact, after simulation of a posterior medial meniscus root tear (PMMR tear) and after medial meniscectomy (MM), represented by R-squared values (n = 6, mean ± standard deviation).

Intact PMMR tear MM
Swing phase Stance phase Swing phase Stance phase Swing phase Stance phase
Viscous friction model Crisco et al. (2007) 0.997 ± 0.002 0.990 ± 0.013 0.996 ± 0.003 0.990 ± 0.007 0.995 ± 0.002 0.940 ± 0.093
Boundary friction model Stanton (1923) 0.661 ± 0.103 0.642 ± 0.137 0.573 ± 0.125 0.571 ± 0.249 0.655 ± 0.107 0.517 ± 0.122