Performance comparison of EMD-based seizure detection method for epileptic seizure.

Decomposition Method Sensitivity% Specificity % Accuracy % Mean Parametric Value (%) Classifiers CV
Complete ensemble empirical mode decomposition with adaptive noise [11]-sets S and (F) 100 99 98 99 RF 10
Complete ensemble empirical mode decomposition with adaptive noise [11]-sets S and (F, N) 99.50 100.00 99.00 99.50 RF 10
Variational mode decomposition [16] - - 97.35 - RF 10
Hilbert vibration decomposition [17] 96 97.5 97.33 96.94 LS_SVM 10
99 99 97.67 98.56 LS_SVM 10