Table 3.
Sensors | Measuring Range | Measuring Accuracy | Operating Temperature | Warning Range |
---|---|---|---|---|
Temperature | −55–125 °C | ±0.5 °C @ −10–85 °C | −55–125 °C | ≤0 °C or ≥40 |
pH | 0–14 | ±0.1 @ 25 °C | 0–60 °C | <6.5 or >8.5 |
DO | 0–20 mg/L | NA | 0–50 °C | ≤6 mg/L |
EC | 0–20 mS/cm | ±5% F.S. | 0–40 °C | ≥5 mS/cm |