Skip to main content
. 2021 Dec 7;21(24):8179. doi: 10.3390/s21248179

Table 3.

Main specification and warning range of aquatic sensors.

Sensors Measuring Range Measuring Accuracy Operating Temperature Warning Range
Temperature −55–125 °C ±0.5 °C @ −10–85 °C −55–125 °C ≤0 °C or ≥40
pH 0–14 ±0.1 @ 25 °C 0–60 °C <6.5 or >8.5
DO 0–20 mg/L NA 0–50 °C ≤6 mg/L
EC 0–20 mS/cm ±5% F.S. 0–40 °C ≥5 mS/cm