Table 2.

Comparison of the reactivity of mouse mAbs W6/32, HC-10 and TFL-006 with HLA-I coated three different beadsets A, B and C. For the commercial sources and the brand names of the beadsets refer to Materials and methods.

mAbs tested Loci n Beadset Median MFI ± SD MFi range p value vs Beadset C
W6/32 HLA-A 27 A 21,664 ± 950 19,008–22,513 < 0.0001
B 17,159 ± 1978 11,450–19,860 < 0.0754
C 17,308 ± 2240 13,663–21,638
HLA-B 44 A 21,811 ± 1568 16,084–23,072 < 0.0001
B 17,481 ± 3178 10,433–21,406 0.0002
C 19,635 ± 2392 10,863–22,887
HLA-Cw 13 A 18,797 ± 3768 11,436–23,742 0.0015
B 13,258 ± 4196 4918–18,639 0.75
C 10,825 ± 3095 5336–15,299
HC-10 HLA-A 10 A 10,645 ± 4274 5038–17,797 0.0051
B 3732 ± 1882 1488–7112 0.0051
C 426 ± 256 97–905
HLA-B 42 A 14,066 ± 3859 3057–19,455 < 0.0001
B 1202 ± 1296 370–6922 0.028
C 838 ± 1253 67–5736
HLA-Cw 13 A 18,322 ± 3115 12,096–21,774 0.0015
B 732 ± 686 455–2650 0.13
C 791 ± 423 231–1627
TFL-006 HLA-A 27 A 1172 ± 1312 242–6907 < 0.0001
B 231 ± 338 80–1468 < 0.0001
C 1 ± 1 0–5
HLA-B 44 A 2257 ± 1158 205–4806 < 0.0001
B 13 ± 45 4–225 < 0.0001
C 0 ± 1 0–6
HLA-Cw 13 A 3702 ± 1932 1852–7733 0.0015
B 18 ± 18 9–72 0.0019
C 2 ± 5 0–15