Skip to main content
. 2021 Sep;32(3):137–147. doi: 10.7171/jbt.21-32-03-009

TABLE 3.

Reverse-transcription loop-mediated isothermal amplification (RT-LAMP) results for 10-fold and 100-fold dilutions of 13 severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2)–positive samples from University of Wisconsin Hospitals and Clinics (UWHC)


Sample

1:10 dilution result

1:100 dilution result

Undiluted vRNA load (copies/μL)
UWHC1 1/2 0/2 3.25 × 102
UWHC2 0/2 0/2 10.9
UWHC3 2/2 2/2 5.17 × 104
UWHC4 2/2 2/2 3.57 × 103
UWHC5 1/2 0/2 6.81 × 102
UWHC6 0/2 0/2 37.4
UWHC7 0/2 0/2 0.701
UWHC8 1/2 0/2 8.10 × 102
UWHC9 0/2 0/2 0.402
UWHC10 2/2 0/2 3.72 × 103
UWHC11 2/2 1/2 1.10 × 104
UWHC12 0/2 0/2 1.75
UWHC13 0/2 0/2 1.14

Abbreviation: vRNA, viral RNA.