Skip to main content
. 2021 Dec 23;12:714313. doi: 10.3389/fneur.2021.714313

Table 4.

Receiver operating characteristics curves of collateral-related parameters for evaluating clinical outcome.

Variables AUC (95% CI) Sensitivity (95% CI) Specificity (95% CI) Youden index Associated criterion P
tMIP CTA VCCq 0.93(0.85,1.00) 0.88(0.56,0.94) 0.80(0.39,1.00) 0.68 −0.84 <0.001
sCTA VCCq 0.74(0.63,0.85) 0.71(0.38,0.94) 0.66(0.39,0.86) 0.47 0.03 <0.001
Tan score on sCTA 0.56(0.43,0.70) 0.74(0.28,0.99) 0.73(0.19,0.99) 0.47 2.50 0.307
Tan score on tMIP CTA 0.79(0.68,0.89) 0.50(0.07,0.90) 0.98(0.30,1.00) 0.48 −1.00 <0.001
IP volume 0.52(0.39,0.65) 0.50(0.23,0.79) 0.49(0.27,0.75) 0.00 248.96 0.727
IC volume 0.71(0.58,0.83) 0.65(0.47,0.77) 0.60(0.25,0.94) 0.25 52.69 0.002
Mismatch ratio 0.70(0.57,0.82) 0.71(0.44,0.82) 0.61(0.26,0.90) 0.32 9.05 0.002

AUC, area under the curve; CI, confidence interval; tMIP CTA, time maximum intensity projection computed tomography angiography; sCTA, single-phase computed tomography angiography; tMIP CTA VCCq, quantitative measurement of vascular volume ratio on tMIP CTA; sCTA VCCq, quantitative measurement of vascular volume ratio on sCTA.