Skip to main content
. 2021 Sep 17;17(1):55–64. doi: 10.1007/s11548-021-02489-9

Table 1.

Summary of the patients recruited for this study and the surgical parameters used in the finite element model to replicate the genioplasty segment repositioning: horizontal displacement UH (a: anterior direction, p: posterior direction), vertical displacement UV (cra: cranial direction, cau: caudal direction), rotation ϑ (c: clockwise, cc: counterclockwise), osteotomy height H, osteotomy angle α

Patient Sex Age at procedure (years) UHS (mm) UVS (mm) ϑS (°) HS (mm) αS (°)
P1 F 16 2 (a) 0 10 (cc) 14.0 13.0
P2 F 19 4 (a) 1 (cau) 11.7 (cc) 20.3 10.4
P3 M 24 1 (p) 1 (cra) 8 (c) 24.0 5.7
P4 F 17 0.5 (a) 0.5 (cau) 8.4 (cc) 22.0 15.0
P5 F 32 2 (a) 2 (cra) 16 (cc) 18.0 19.0
P6 F 35 2 (a) 4 (cau) 8 (cc) 26.5 3.0
P7 F 39 1 (a) 1.5 (cau) 5 (cc) 26.0 2.0