Skip to main content
. 2021 Dec 31;33(6):682–693. doi: 10.21147/j.issn.1000-9604.2021.06.05

Table S10. Performance of the model in prospective clinical application in each center (by patients).

Variables Prospective application performance (N=5,746)
Center A (n=1,450) Center B (n=1,454) Center C (n=958) Center D (n=1,098) Center E (n=279) Center F (n=507)
95% CI, 95% confidence interval; PPV, positive predictive value; NPV, negative predictive value.
Accuracy
(95% CI)
0.959
(0.948, 0.969)
0.959
(0.949, 0.969)
0.986
(0.979, 0.994)
0.970
(0.960, 0.980)
0.941
(0.913, 0.969)
0.989
(0.979, 0.998)
Sensitivity
(95% CI)
0.754
(0.699, 0.810)
0.674
(0.575, 0.773)
0.806
(0.714, 0.897)
0.690
(0.551, 0.830)
0.742
(0.588, 0.896)
0.778
(0.642, 0.914)
Specificity
(95% CI)
0.965
(0.954, 0.975)
0.979
(0.971, 0.986)
0.984
(0.976, 0.992)
0.985
(0.977, 0.992)
0.976
(0.957, 0.995)
0.996
(0.990, 1.002)
PPV
(95% CI)
0.800
(0.747, 0.853)
0.667
(0.568, 0.766)
0.806
(0.714, 0.897)
0.644
(0.505, 0.784)
0.793
(0.646, 0.941)
0.933
(0.844, 1.023)
NPV
(95% CI)
0.955
(0.943, 0.966)
0.980
(0.972, 0.987)
0.984
(0.976, 0.992)
0.988
(0.981, 0.994)
0.968
(0.946, 0.990)
0.983
(0.972, 0.995)